Identification of proprietary piping system

Advisory note08/2023
ForLicensees and contractors working in the gasfitting industry
ScopeApplies to all areas in New South Wales

Issue

Recent gas audit inspections of Class 1 and 2 buildings carried out by Fair Trading’s Gas Compliance Unit have identified a failure to ensure Identification of the proprietary piping system that is installed.

All gas installations in NSW must comply with the Gas and Electricity (Consumer Safety) Act 2017 with any installation not conforming to AS/NZS 5601.1:2022 considered non-compliant.

Reference

Gas and Electricity [Consumer Safety] Regulation 2018

AS/NZS 5601.1:2022 - Gas Installations

4.5.4 – Identification of proprietary piping systems

The maker or trade name of the proprietary system shall be identified on a durable label attached adjacent to the gas meter, LP Gas tank, cylinder(s) or any other supply point.

Requirements:

When a proprietary piping system (multilayer gas piping system) is used in a gas installation, the maker or trade name of the proprietary system shall be identified on a durable label attached adjacent to the gas meter, LP Gas tank, cylinder(s) or any other supply point.

Examples of Identification labels can be found below.

Image example of a Rautitan multilayer gas piping identification label Image example of a GasPex multilayer gas piping identification label Image example of an Elson multilayer gas piping identification label



For more information, please email: [email protected]

This advisory note has been approved for issue by the BSCU Technical Review Committee. Information contained within this document is current as of January 2023 and refers to codes and standards current at the time of writing.

NSW Fair Trading disclaims any liability (including for negligence) to any person in respect of anything done, or not done, by that person in whole or partial reliance on any of the information in this advisory note.

Prev Damaged pipes and/or fittings installed in consumer gas pipework
Next Emergency isolation for installations containing multilayer pipe